1. electric hot water tank with 24 VDC elements, used as water heating diversion load
2. air heating diversion load
3. switch to select air, water, or both diversion loads
4. 24 VDC breakers
5. 24 VDC disconnect
6. main house 120 VAC breakers
7. 12 VDC breakers
8. 12 VDC disconnect
9. battery box vent & Power Vent suction fan
10. Enermaxer Battery Voltage Regulator (load diversion control)
11. wires in from PV panels
12. wires in from wind generator
13. wind generator control (brake and AC-DC rectifiers)
14. PV disconnect
15. rectifier to prevent current back-flow through PV panels at night
16. conduit from inverter outputs to AC breaker panel
17. conduit from gas generator to inverter #1
18. leads from battery bank to inverters
19. buss bar for meter 500a shunt
20. Trace 4024 inverter #1
21. Trace 4024 inverter #2
22. 24 VDC battery bank (20 T105 Trojans) and battery box with plexiglas cover
23. battery box pressure fan (comes on 0.2 volts higher than suction fan)
24. lots of distilled water
25. Vanner battery equalizer (supplies 12 VDC evenly from 24 VDC battery bank)
26. ammeter showing current going to water heating diversion load